You are currently viewing the User Testing Site.
NA6.2 Default U-factor
Equation NA6-1

UT= C1 + (C2 X Uc)

Where:

UT = U-factor Is the Total Performance of the fenestration including glass and frame

C1 = Coefficient selected from Table NA6-6

C2 = Coefficient selected from Table NA6-6

UC = Center of glass U-factor calculated in accordance with NFRC 100 Section 4.5.3.1 (http://www.nfrc.org/software.aspx)

Table NA6-6 – U-factor Coefficients
Product Type
Frame Type
C 1
C 2
Site-Built Vertical Fenestration
Metal
0.311
0.872
Site-Built Vertical Fenestration
Metal Thermal Break
0.202
0.867
Site-Built Vertical Fenestration
Non-Metal
0.202
0.867
Skylights with a Curb
Metal
0.711
1.065
Skylights with a Curb
Metal Thermal Break
0.437
1.229
Skylights with a Curb
Non-Metal
0.437
1.229
Skylights with no Curb
(Deck Mounted)
Metal
0. 310
0. 878
Skylights with no Curb
(Deck Mounted)
Metal Thermal Break
0. 195
0. 882
Skylights with no Curb
(Deck Mounted)
Non-Metal
0.310
0.878