13.107 Envelope

NRCA-ENV-02-F – Fenestration Acceptance Certificate

The form is separated into two basic sections: project information; general information; and declaration statement of acceptance. Each section consists of a combination of data entry requirements and check boxes.

Project Information

•      PROJECT NAME is the title of the project, as shown on the Code Compliance forms.

•      DATE is the date of preparation of the compliance submittal package.

•      PROJECT ADDRESS is the address of the project as shown on the Code Compliance forms.

•      TESTING AUTHORITY is the person responsible for verifying all acceptance tests were performed and each system passed.

General Information

This section consists of a combination of data entry requirements and check boxes, all of which are self-explanatory. Complete check boxes and enter data as instructed.

Statement of Acceptance

This section consists of a combination of check boxes and data entry requirements, including signature; date; and license number. Complete check boxes and enter data as instructed.

 

NRCA-ENV-02-F – Fenestration Acceptance Page 2 of 2

The form is used to document the overall final results of all acceptance tests. The Responsibility Party shall verify the thermal performance (U-factor, SHGC and VT) of each specified fenestration product being installed. The Responsible Party ensures that each product matches the fenestration certificate, energy compliance documentation and building plans.

Summary of Acceptance Tests

•      FENESTRATION PRODUCT MODELS are listed for each column representing one product. Additional sheets may be required to document each product line beyond four.

•      MANUFACTURED PRODUCT CODE – should match either the NFRC or Energy Commission Label Certificate.

•      NFRC CERTIFIED PRODUCT DIRECTORY, CPD, Indicate the CPD number to include dashes between the numbers.

•      ENFORCEMENT AGENCY VERIFICATION  The Enforcement Agency may optionally verify any Fenestration being installed for authenticity by accessing http://cmast.nfrc.org/Project/CertificateFind.aspx for NFRC CMAST Certificate Labels or NFRC Certificate Labels http://search.nfrc.org/search/searchDefault.aspx.

•      PROOF – Check box only after verification of each product line is complete. If products do not match, the enforcement agency may have the option to stop installation and re-comply with energy compliance for installing less thermal performance as indicated in the energy compliance documentation, building plans and receipt or Purchase Order.