Appendix B: Excerpts from the Appliance Efficiency Regulations

Table T-1
Normal Impedance Ranges for Liquid-Immersed Transformers

Single‐phase

Three‐phase

kVA

Impedance (%)

kVA

Impedance (%)

10

1.0–4.5

15

1.0–4.5

15

1.0–4.5

30

1.0–4.5

25

1.0–4.5

45

1.0–4.5

37.5

1.0–4.5

75

1.0–5.0

50

1.5–4.5

112.5

1.2–6.0

75

1.5–4.5

150

1.2–6.0

100

1.5–4.5

225

1.2–6.0

167

1.5–4.5

300

1.2–6.0

250

1.5–6.0

500

1.5–7.0

333

1.5–6.0

750

5.0–7.5

500

1.5–7.0

1000

5.0–7.5

667

5.0–7.5

1500

5.0–7.5

833

5.0–7.5

2000

5.0–7.5

 

 

2500

5.0–7.5

 

Table T-2
Normal Impedance Ranges for Dry-Type Transformers

Single‐phase

Three‐phase

kVA

Impedance (%)

kVA

Impedance (%)

15

1.5–6.0

15

1.5–6.0

25

1.5–6.0

30

1.5–6.0

37.5

1.5–6.0

45

1.5–6.0

50

1.5–6.0

75

1.5–6.0

75

2.0–7.0

112.5

1.5–6.0

100

2.0–7.0

150

1.5–6.0

167

2.5–8.0

225

3.0–7.0

250

3.5–8.0

300

3.0–7.0

333

3.5–8.0

500

4.5–8.0

500

3.5–8.0

750

5.0–8.0

667

5.0–8.0

1000

5.0–8.0

833

5.0–8.0

1500

5.0–8.0

 

 

2000

5.0–8.0

 

 

2500

5.0–8.0

 

Table A-1
Non-Commercial Refrigerator, Refrigerator-Freezer, and Freezer Test Methods

Appliance

Test Method

Non‐commercial refrigerators, designed for the refrigerated storage of food at temperatures above 32°F and below 39°F, refrigerated food storage; refrigerator‐freezers; and freezers.

10 C.F.R. sections 430.23(a) (Appendix A to Subpart B of part 430) and 430.23(b) (Appendix B to Subpart B of part 430)

Wine chillers that are consumer products

10 C.F.R. section 430.23(a) (Appendix A1 to Subpart B of part 430), with the following modifications:

Standardized temperature as referred to in Section 3.2 of Appendix A1 shall be 55°F (12.8°C).

The calculation of test ’cycle energy expended (ET) in section 5.2.1.1 of Appendix A1 shall be made using the modified formula:

ET=(EP x 1440 x k)/T
Where k = 0.85

 

Table A-2
Commercial Refrigerator, Refrigerator-Freezer, and Freezer Test Methods

Appliance

Test Method

Automatic commercial ice makers

10 C.F.R. sections 431.133 and 431.134

Refrigerated bottled or canned beverage vending machines

10 C.F.R. sections 431.293 and 431.294

Refrigerated buffet and preparation tables

ANSI/ASTM F2143‐01

Other commercial refrigerators, ‘refrigerator‐freezers, and ‘freezers, with doors

10 C.F.R. sections 431.63 and 431.64

Other commercial refrigerators, refrigerator‐freezers, and freezers, without doors

10 C.F.R. sections 431.63 and 431.64

Walk‐in coolers and walk‐in freezers

10 C.F.R. sections 431.303 and 431.304

 

Table B-1
Room Air Conditioner, Room Air-Conditioning Heat Pump,
 Packaged Terminal Air Conditioner, and Packaged Terminal Heat Pump Test Methods

Appliance

Test Method

Room air conditioners and room air‐conditioning heat pumps

10 C.F.R. section 430.23(f) (Appendix F to Subpart B of part 430)

Packaged terminal air conditioners and packaged terminal heat pumps

10 C.F.R. sections 431.95 and 431.96

 

Table C-1
Central Air Conditioner Test Methods

Appliance

Test Method

Computer Room Air Conditioners

evaporatively‐cooled

ANSI/ASHRAE 127‐2001
10 C.F.R. sections 431.95 and 431.96

air‐cooled, glycol‐cooled, water‐cooled

Other electric‐powered unitary air‐conditioners and
 electric powered heat pumps

Air‐cooled air conditioners and air‐source heat pumps

< 65,000 Btu/hr, single‐phase

10 C.F.R. section 430.23(m) (Appendix M to
Subpart B of part 430
)

< 65,000 Btu/hr, three‐phase

10 C.F.R. sections 431.95 and 431.96

≥ 65,000 and < 760,000 Btu/hr

10 C.F.R. sections 431.95 and 431.96

evaporatively‐cooled air conditioners < 240,000 Btu/h

10 C.F.R. sections 431.95 and 431.96

water‐cooled air conditioners and water‐source heat
pumps<240,000 Btu/hr

10 C.F.R. sections 431.95 and 431.96

ground ’water‐source heat pumps

ARI/ISO‐13256‐1:1998

ground‐source closed‐loop heat pumps

ARI/ISO‐13256‐1:1998

Variable Refrigerant Flow Multi‐split Systems

10 C.F.R. sections 431.95 and 431.96

Single Package Vertical Air Conditioners and
Single Package Vertical Heat Pumps

10 C.F.R. sections 431.95 and 431.96

’Gas‐fired ‘air conditioners and gas‐fired heat pumps

ANSI Z21.40.4‐1996 as modified by CEC, Efficiency
 Calculation Method for Gas‐Fired Heat Pumps as a
New Compliance Option (1996)

 

Table D-1
Spot Air Conditioner, Ceiling Fan, Ceiling Fan Light Kit, Evaporative Cooler,
Whole House Fan, Residential Exhaust Fan, and Dehumidifier Test Methods

Appliance

Test Method

Spot ’Air Conditioners

ANSI/ASHRAE 128‐2001

Ceiling Fans, Except Low‐Profile Ceiling Fans

10 C.F.R. section 430.23(w) (Appendix U to Subpart B of part 430)

Ceiling Fan Light Kits

10 C.F.R. section 430.23(x) (Appendix V to Subpart B of part 430)

Evaporative Coolers

ANSI/ASHRAE 133‐2008 for packaged direct evaporative coolers and packaged indirect/direct evaporative coolers; ANSI/ASHRAE 143‐2007 for packaged indirect evaporative coolers

Whole House Fans

HVI‐Publication 916, 29 September 2015 HVI Airflow Test Procedure, as specified in section 5.2

Use setups for whole house comfort ventilatiors.

Dehumidifiers

10 C.F.R. section 430.23(z) (Appendix X to Subpart B of part 430, active mode portion only)

Residential Exhaust Fans

HVI‐Publication 916, 29 September 2015 HVI Airflow Test Procedure, as specified in section 5.2

Residential Furnace Fans

10 C.F.R. section 430.23(cc) (Appendix AA to Subpart B of part 430)

 

Table E-1
Vented gas space heaters and vented oil space heaters, vented and unvented infrared gas heaters,
electric residential boilers, and gas‐fired combination space‐heating and water‐heating appliances Test Methods

Appliance

Test Method

Central furnaces

< 225,000 Btu/hr, single phase

10 C.F.R. section 430.23(n) (Appendix N to Subpart B of part 430)

< 225,000 Btu/hr, three phase

10 C.F.R. section 430.23(n) (Appendix N to Subpart B of part 430) or 10 C.F.R. sections 431.75 and 431.76 (at manufacturer’s option)

≥ 225,000 Btu/hr

10 C.F.R. sections 431.75 and 431.76

‘Gas infrared heaters

patio heaters

ASTM F2644‐07

  gas‐fired high‐intensity infrared heaters

ANSI Z83.19‐2001

  gas‐fired low‐intensity infrared heaters

ANSI Z83.20‐2001

Unit heaters

 gas‐fired

ANSI Z83.8‐2002*

 oil‐fired

UL 731‐1995*

Gas duct furnaces

ANSI Z83.8‐2002

Boilers

< 300,000 Btu/hr

10 C.F.R. section 430.23(n) (Appendix N to Subpart B of part 430)

≥ 300,000 Btu/hr

10 C.F.R. sections 431.85 and 431.86

Wall furnaces, floor furnaces, and room heaters

10 C.F.R. section 430.23(o) (Appendix O to Subpart B of part 430)

*To calculate maximum energy consumption during standby, measure the gas energy used in one hour (in Btus) and the electrical energy used (in watt‐hours) over a one‐hour period, when the main burner is off. Divide Btus and watt‐hours by one hour to obtain Btus per hour and watts. Divide Btus per hour by 3.412 to obtain watts. Add watts of gas energy to watts of electrical energy to obtain standby energy consumption in watts.

 

Table F-1
Small Water Heater Test Methods

Appliance

Test Method

Small water heaters that are federally‐regulated consumer products

10 C.F.R. part 430, Subpart B, Appendix E, section 5: “Test Procedures” and part 430.23(e)(4): “The alternative uniform test method for measuring the energy consumption of untested water heaters shall be that set forth in section 7.0 of Appendix E of this subpart.”

Small water heaters that are not federally‐regulated consumer products

’Gas and oil storage‐type < 20 gallons rated capacity

ANSI/ASHRAE 118.2‐1993

Booster water heaters

ANSI/ASTM F2022‐00 (for all matters other than volume) ANSI Z21.10.3‐1998 (for volume)

Hot ’water dispensers

Test Method in 1604(f)(4)

Mini‐tank electric water heaters

Test Method in 1604(f)(5)

All others

10 C.F.R. section 430.23(e) (Appendix E to Subpart B of part 430)

 

Table G-1
Pool Heater Test Methods

Appliance

Test Method

’Gas‐fired and oil‐fired ’pool heaters

10 C.F.R. section 430.23(p) (Appendix P to Subpart B of part 430)

Electric resistance ‘pool heaters

ANSI/ASHRAE 146‐1998

Heat pump pool heaters

ANSI/ASHRAE 146‐1998, as modified by Addendum Test Procedure published by Pool Heat Pump Manufacturers Association dated April, 1999, Rev 4: Feb. 28, 2000:

Reading

Standard Temperature Rating

Low‐Temperature Rating

Spa Conditions Rating

Air Temperature
Dry‐bulb
Wet‐bulb


27.0°C (80.6°F)

21.7°C (71.0°F)


10.0°C (50.0°F)
6.9°C (44.4°F)


27.0°C (80.6°F)
21.7°C (71.0°F)

Relative Humidity

63%

63%

63%

Pool Water Temperature

26.7°C (80.0°F)

26.7°C (80.0°F)

40.0°C (104.0°F)

 

Table R-1
Cooking Product and Food Service Equipment Test Methods

Appliance

Test Method

Cooking products that are consumer products

10 C.F.R. section 430.23(i) (Appendix I to Subpart B of part 430)

Commercial hot food holding cabinets

ANSI/ASTM F2140-01 (Test for idle energy rate-dry test) and US EPA’s Energy Star Guidelines, “Measuring Interior Volume” (Test for interior volume)

Commercial convection ovens

ANSI/ASTM F1496-99 (Test for energy input rate and idle energy consumption only)

Commercial range tops

ANSI/ASTM F1521-96 (Test for cooking energy efficiency only)

 

Table A-3
Standards for Non-Commercial Refrigerators, Refrigerator-Freezers, and Freezers

Appliance

Defrost

Compact, Built‐ in, Neither

Ice

Maximum Energy Consumption (kWh/year)

Equipped with Automatic Ice Maker?

Dispense Ice Through Door?

July 1, 20011

Sept. 15, 20142

Refrigerators

Not ‘all refrigerator’

Manual

Neither

‐‐

‐‐

8.82AV + 248.4

7.99AV + 225.0

Not ‘all refrigerator’

Manual

Compact

‐‐

‐‐

10.70AV + 299.0

9.03AV + 252.3

‘All refrigerator’

Manual

Compact

‐‐

‐‐

10.70AV + 299.0

7.84AV + 219.1

‘All refrigerator’

Manual

Neither

‐‐

‐‐

‐‐

6.79AV + 193.6

‘All refrigerator’

Automatic

Neither

‐‐

‐‐

9.80AV + 276.0

7.07AV + 201.6

‘All refrigerator’

Automatic

Built‐in

‐‐

‐‐

‐‐

8.02AV + 228.5

‘All refrigerator’

Automatic

Compact

‐‐

‐‐

12.70AV + 355.0

9.17AV + 259.3

Refrigerator‐freezers

 

Manual

Neither

‐‐

‐‐

8.82AV + 248.4

7.99AV + 225.0

Partial

Neither

‐‐

‐‐

8.82AV + 248.4

7.99AV + 225.0

Manual

Compact

‐‐

‐‐

‐‐

9.03AV + 252.3

Partial

Compact

‐‐

‐‐

7.00AV + 398.0

5.91AV + 335.8

Refrigerator‐‘freezers Bottom‐‘Freezer

 

Automatic

Neither

No

‐‐

4.60AV + 459.0

8.85AV + 317.0

Automatic

Neither

Yes

No

‐‐

8.85AV + 401.0

Automatic

Neither

Yes

Yes

‐‐

9.25AV + 475.4

Automatic

Compact

No

‐‐

13.10AV + 367.0

11.80AV + 339.2

Automatic

Compact

Yes

‐‐

‐‐

11.80AV + 423.2

Automatic

Built‐in

No

‐‐

‐‐

9.40AV + 336.9

Automatic

Built‐in

Yes

No

‐‐

9.40AV + 420.9

Automatic

Built‐in

Yes

Yes

‐‐

9.83AV + 499.9

Refrigerator‐freezers  Side‐by‐side

 

Automatic

Neither

No

‐‐

4.91AV+507.5

8.51AV + 297.8

Automatic

Neither

Yes

No

‐‐

8.51AV + 381.8

Automatic

Neither

Yes

Yes

10.10AV + 406.0

8.54AV + 432.8

Automatic

Compact

No

‐‐

7.60AV + 501.0

6.82AV + 456.9

Automatic

Compact

Yes

‐‐

‐‐

6.82AV + 540.9

Automatic

Built‐in

No

‐‐

‐‐

10.22AV + 357.4

Automatic

Built‐in

Yes

No

‐‐

10.22AV + 441.4

Automatic

Built‐in

Yes

Yes

‐‐

10.25AV + 502.6

Refrigerator‐freezers  Top‐Freezer

 

Automatic

Neither

No

‐‐

9.80AV + 276.0

8.07AV + 233.7

 

Automatic

Neither

Yes

No

‐‐

8.07AV + 317.7

 

Automatic

Neither

Yes

Yes

10.20AV + 356.0

8.40AV + 385.4

 

Automatic

Compact

No

‐‐

12.70AV + 355.0

11.80AV + 339.2

¹AV = adjusted total volume, expressed in ft3, as determined in 10 C.F.R., part 430, Appendices A1 and B1 of Subpart B, which is: [1.44 x freezer volume (ft3)] + refrigerator volume (ft3) for refrigerators;
[1.63 x freezer volume (ft3)] + refrigerator volume (ft3) for refrigerator‐freezers; [1.73 x freezer volume (ft3)] for freezers.
²AV = adjusted total volume, expressed in ft3, as determined in 10 C.F.R., part 430, Appendices A and B of Subpart B.

 

Table A-4
Standards for Commercial Refrigerators, Refrigerator-Freezers
with a Self-Contained Condensing Unit That are Not Commercial Hybrid Units

Equipment Category and Effective Date

Condensing Unit Configuration

Equipment Family

Rating Temperature
(°F)

Operating Temperature
(°F)

Equipment Class Designation*

Maximum Daily Energy Consumption (kWh)

Refrigerators and Freezers Effective
January 1, 2010




Effective
January 1, 2012

Self Contained (SC)

Vertical Closed Transparent (VCT)

38 (M)
0 (L)

≥ 32
< 32

VCT, SC, M
VCT, SC, L

0.12 × V + 3.34
0.75 × V + 4.10

Horizontal Closed Transparent (HCT)

38 (M)
0 (L)

≥ 32
< 32

HCT, SC, M
HCT, SC, L

0.12 × V + 3.34
0.75 × V + 4.10

Vertical Closed Solid (VCS)

38 (M)
0 (L)

≥ 32
< 32

VCS, SC, M
VCS, SC, L

0.10 × V + 2.04
0.40 × V + 1.38

Horizontal Closed Solid (HCS)

38 (M)
0 (L)

≥ 32
< 32

HCS, SC, M
HCS, SC, L

0.10 × V + 2.04
0.40 × V + 1.38

Service Over Counter (SOC)

38 (M)
0 (L)

≥ 32
< 32

SOC, SC, M
SOC, SC, L

0.12 × V + 3.34
0.6  TDA + 1.0
0.75 × V + 4.10

Refrigerators with transparent doors designed for pull-down temperature applications.

Effective January 1, 2010

Self Contained (SC)

Vertical Closed Transparent (VCT)

38 (P)

≥ 32

VCT, SC, P

0.126 × V + 3.51

Horizontal Closed Transparent (HCT)

38 (P)

≥ 32

HCT, SC, P

0.126 × V + 3.51

Refrigerators and Freezers without Doors Effective January 1, 2012

Self Contained (SC)

Vertical Open (VOP)

38 (M)
0 (L)

≥ 32
< 32

VOP, SC, M
VOP, SC, L

1.74 × TDA + 4.71
4.37 × TDA +11.82

Semivertical Open (SVO)

38 (M)
0 (L)

≥ 32
< 32

SVO, SC, M
SVO, SC, L

1.73 × TDA + 4.59
4.34 × TDA +11.51

Horizontal Open (HZO)

38 (M)
0 (L)

≥ 32
< 32

HZO, SC, M
HZO, SC, L

0.77 × TDA + 5.55
1.92 × TDA + 7.08

* The meaning of the letters in this column is indicated in the Condensing Unit Configuration, Equipment Family, and Rating Temperature (°F) columns to the left.

 

Table A-5
Standards for Commercial Refrigerators and Freezers
with a Remote Condensing Unit That are Not Commercial Hybrid Units

Equipment Category

Condensing Unit Configuration

Equipment Family

Rating Temperature (°F)

Operating Temperature (°F)

Equipment Class Designation*

Maximum Daily Energy Consumption (kWh)

Refrigerators and Freezers Effective January 1, 2012

‘Remote (RC)

Vertical Open (VOP)

38 (M)
0 (L)

≥ 32
< 32

VOP, RC, M
VOP, RC, L

0.82 × TDA + 4.07
2.27 × TDA + 6.85

Semivertical Open (SVO)

38 (M)
0 (L)

≥ 32
< 32

SVO, RC, M SVO, RC, L

0.83 × TDA + 3.18
2.27 × TDA + 6.85

Horizontal Open (HZO)

38 (M)
0 (L)

≥ 32
< 32

HZO, RC, M
HZO, RC, L

0.35 × TDA + 2.88
0.57 × TDA + 6.88

Vertical Closed Transparent (VCT)

38 (M)
0 (L)

≥ 32
< 32

VCT, RC, M
VCT, RC, L

0.22 × TDA + 1.95
0.56 × TDA + 2.61

Horizontal Closed Transparent (HCT)

38 (M)
0 (L)

≥ 32
< 32

HCT, RC, M
HCT, RC, L

0.16 × TDA + 0.13
0.34 × TDA + 0.26

Vertical Closed Solid (VCS)

38 (M)
0 (L)

≥ 32
< 32

VCS, RC, M
VCS, RC, L

0.11 × V + 0.26
0.23 × V + 0.54

Horizontal Closed Solid (HCS)

38 (M)
0 (L)

≥ 32
< 32

HCS, RC, M
HCS, RC, L

0.11 × V + 0.26
0.23 × V + 0.54

Service Over
Counter (SOC)

38 (M)
0 (L)

≥ 32
< 32

SOC, RC, M
SOC, RC, L

0.51 × TDA + 0.11
1.08 × TDA + 0.22

* The meaning of the letters in this column is indicated in the Condensing Unit Configuration, Equipment Family, and Rating Temperature (°F) columns to the left.

 

Table A-7
Standards for Automatic Commercial Ice Makers Manufactured on or After January 1, 2010

Equipment type

Type of cooling

Harvest rate
(lbs ice/24 hours)

Maximum ‘energy use (kWh/100 lbs ice)

Maximum condenser water use*
 (gal/100 lbs ice)

Ice Making Head

Water

< 500

7.80–0.0055H

200–0.022H.

Ice Making Head

Water

≥ 500 and < 1436

5.58–0.0011H

200–0.022H.

Ice Making Head

Water

≥ 1436

4.0

200–0.022H.

Ice Making Head

Air

< 450

10.26–0.0086H

Not applicable.

Ice Making Head

Air

≥ 450

6.89–0.0011H

Not applicable.

Remote Condensing (but not remote compressor)

Air

< 1000

8.85–0.0038H

Not applicable.

Remote Condensing (but not remote compressor)

Air

≥ 1000

5.1

Not applicable.

Remote Condensing and Remote Compressor

Air

< 934

8.85–0.0038H

Not applicable.

Remote Condensing and Remote Compressor

Air

≥ 934

5.3

Not applicable.

Self Contained

Water

< 200

11. 40–0.019H

191–0.0315H.

Self Contained

Water

≥ 200

7.6

191–0.0315H.

Self Contained

Air

< 175

18.0–0.0469H

Not applicable.

Self Contained

Air

≥ 175

9.8

Not applicable.

H Harvest rate in pounds per 24 hours.

*Water use is for the condenser only and does not include potable water used to make ice.

 

Table B-2
Standards for Room Air Conditioners and Room Air-Conditioning
Heat Pumps Manufactured on or After October 1, 2000 and Before June 1, 2014

Appliance

Louvered Sides

Cooling Capacity (Btu/hr)

Minimum EER

Room ‘Air Conditioner

Yes

< 6,000

9.7

Room Air Conditioner

Yes

> 6,000 – 7,999

9.7

Room Air Conditioner

Yes

> 8,000 – 13,999

9.8

Room Air Conditioner

Yes

> 14,000 – 19,999

9.7

Room Air Conditioner

Yes

> 20,000

8.5

Room Air Conditioner

No

< 6,000

9.0

Room Air Conditioner

No

> 6,000 – 7,999

9.0

Room Air Conditioner

No

> 8,000 – 19,999

8.5

Room Air Conditioner

No

> 20,000

8.5

Room Air Conditioning Heat Pump

Yes

< 20,000

9.0

Room Air Conditioning Heat Pump

Yes

> 20,000

8.5

Room Air Conditioning Heat Pump

No

< 14,000

8.5

Room Air Conditioning Heat Pump

No

> 14,000

8.0

Casement‐Only Room Air Conditioner

Either

Any

8.7

Casement‐Slider Room Air Conditioner

Either

Any

9.5

 

Table B-3
Standards for Room Air Conditioners and Room Air-Conditioning
 Heat Pumps Manufactured On or After June 1, 2014

Appliance

Louvered Sides

Cooling Capacity
(Btu/hr)

Minimum Combined EER

Room ‘Air Conditioner

Yes

< 6,000

11.0

Room Air Conditioner

Yes

> 6,000 – 7,999

11.0

Room Air Conditioner

Yes

> 8,000 – 13,999

10.9

Room Air Conditioner

Yes

> 14,000 – 19,999

10.7

Room Air Conditioner

Yes

> 20,000 – 27,999

9.4

Room Air Conditioner

Yes

> 28,000

9.0

Room Air Conditioner

No

< 6,000

10.0

Room Air Conditioner

No

> 6,000 – 7,999

10.0

Room Air Conditioner

No

> 8,000 – 10,999

9.6

Room Air Conditioner

No

> 11,000 – 13,999

9.5

Room Air Conditioner

No

> 14,000 – 19,999

9.3

Room Air Conditioner

No

> 20,000

9.4

Room Air Conditioning Heat Pump

Yes

< 20,000

9.8

Room Air Conditioning Heat Pump

Yes

> 20,000

9.3

Room Air Conditioning Heat Pump

No

< 14,000

9.3

Room Air Conditioning Heat Pump

No

> 14,000

8.7

Casement‐Only Room Air Conditioner

Either

Any

9.5

Casement‐Slider Room Air Conditioner

Either

Any

10.4

 

Table C-3
Standards for Single Phase Air-Cooled Air Conditioners with Cooling Capacity
Less than 65,000 Btu per Hour and Single Phase Air-Source Heat Pumps
 with Cooling Capacity Less than 65,000 Btu per Hour, Not Subject to EPAct

Appliance

Minimum ‘Efficiency

Effective January 23, 2006

Effective January 1, 2015

Minimum SEER

Minimum HSPF

Minimum SEER

Minimum HSPF

Minimum EER

Average Off‐ Mode Power Consumption Pw. pff (watts)

Split system ‘air conditioners with rated cooling capacity < 45,000 Btu/hour¹

13.0

—

14.0

—

12.2

30

Split system air conditioners with rated cooling capacity ≥ 45,000 Btu/hour¹

14.0

—

11.7

30

Split system ‘heat pumps

13.0

7.7

14.0

8.2

—

33

Single package air conditioners¹

13.0

—

14.0

—

11.0

30

Single package heat pumps

13.0

7.7

14.0

8.0

—

33

Space constrained air conditioners – split system

12.0

 

12.0

—

—

30

Space constrained heat pumps – split system

12.0

7.4

12.0

7.4

—

33

Space constrained air conditioners – single package

12.0

 

12.0

—

—

30

Space constrained heat pumps – single package

12.0

7.4

12.0

7.4

—

33

Small duct, high velocity ‘air conditioner systems

13.0

 

13.0

—

—

30

Small duct, high velocity ‘heat pump systems

13.0

7.7

13.0

7.7

—

30

¹ See 10 C.F.R. section 430.32(c) for less stringent federal standards applicable to these units that are manufactured on or after January 1, 2015 and installed in states other than Arizona, California, Nevada, or New Mexico

 

Table C-4
Standards for Air-Cooled Air Conditioners and Air-Source Heat Pumps Subject to EPAct
 (Standards Effective January 1, 2010 Do Not Apply To Single Package Vertical Air Conditioners)

Appliance

Cooling Capacity (Btu/hr)

System Type

Minimum ‘Efficiency

Effective June 15, 2008

Effective January 1, 2010

Air Conditioners

Heat Pumps

Air‐cooled unitary air conditioners and heat pumps (cooling mode)

< 65,000 *

Split system

13.0 SEER

 

 

< 65,000 *

Single package

13.0 SEER

 

 

≥ 65,000 and< 135,000

All

11.0 EER4

11.2 EER³

10.8 EER4

11.0 EER³

≥ 135,000 and< 240,000

All

 

11.0 EER³

10.8 EER4

10.6 EER³

10.4 EER4

≥ 240,000 and< 760,000

All

 

10.0 EER³

9.8 EER4

9.5 EER³

9.3 EER4

Air‐cooled unitary air conditioning heat pumps (heating mode)

< 65,000 *

Split system

7.7 HSPF

 

< 65,000 *

Single package

7.7 HSPF

 

≥ 65,000 and< 135,000

All

 

3.3 COP

≥ 135,000 and< 240,000

All

 

3.2 COP

≥ 240,000 and< 760,000

All

 

3.2 COP

* Three phase models only.
³ Applies to equipment that has electric resistance heat or no heating.
4 Applies to equipment with all other heating‐system types that are integrated into the unitary equipment.

 

Table C-5
Standards for Water-Cooled Air Conditioners, Evaporatively Cooled
 Air Conditioners, and Water-Source Heat Pumps

Appliance

Cooling Capacity (Btu per hour)

Minimum ‘Efficiency

Effective
Prior to October
29, 2012

Effective January
 10, 2011

Effective
†October 29, 2012 or
††October 29, 2013

Effective
*June 1, 2013 or**June 1, 2014

Minimum
EER          COP

Minimum
EER          COP

Minimum
EER       …COP

Minimum

EER       COP

Water-cooled ‘air conditioners and evaporatively cooled air conditioners

< 17,000

12.1

 

 

 

Water-source ‘heat pumps

< 17,000

11.2

11.2             4.2

 

 

 

Water-source VRF multi-split heat pumps

< 17,000

—

                    4.2

 

12.0¹†

4.2

 

Water-cooled air conditioners and evaporatively cooled air conditioners

> 17,000 and < 65,000

12.1

12.1

 

 

 

Water-source heat pumps, including VRF

> 17,000 and < 65,000

12.0

12.0             4.2

 

 

 

Water-cooled air conditioners and evaporatively cooled air conditioners

> 65,000 and < 135,000

11.5¹

11.51

 

 

12.1¹*       —

Water-source heat pumps, including VRF

> 65,000 and < 135,000

12.0

12.0             4.2

 

 

11.9*         4.2

Water-cooled air conditioners

> 135,000 and < 240,000

11.0

11.0

 

 

12.5¹**      —

Evaporatively cooled air conditioners

> 135,000 and < 240,000

11.0

11.0

 

 

12.0¹**      —

Water-source heat pumps

> 135,000 and < 240,000

11.0

11.0             2.9

 

 

12.3**       2.9

Water-source VRF multi-split heat pumps

> 135,000 and < 760,000

 

 

10.0¹††      3.9††

 

Water-cooled air conditioners

> 240,000 and < 760,000

11.0¹

11.0¹

 

12.4***      —

Evaporatively cooled air conditioners

> 240,000 and < 760,000

11.0¹

11.0¹

 

11.9***      —

Water-source heat pumps

> 240,000 and < 760,000

11.0¹

11.0¹

 

12.2**       —

¹ Deduct 0.2 from the required EER for units with heating sections other than electric resistance heat. For VRF multi-split heat pumps this applies to units with heat recovery.

 

Table C-6
Standards for Single Package Vertical Air Conditioners and Single Package Vertical Heat Pumps Manufactured on or After January 1, 2010

Appliance

Cooling Capacity
(BTU/hr)

System Type

Minimum ‘Efficiency

Cooling Mode

Heating Mode

Single package vertical ‘air conditioners

< 65,000

Single‐phase

9.0 EER

N/A

< 65,000

3‐phase

9.0 EER

N/A

≥ 65,000 and < 135,000

All

8.9 EER

N/A

≥ 135,000 and < 240,000

All

8.6 EER

N/A

Single package vertical ‘heat pumps

< 65,000

Single‐phase

9.0 EER

3.0 COP

< 65,000

3‐phase

9.0 EER

3.0 COP

≥ 65,000 and < 135,000

All

8.9 EER

3.0 COP

≥ 135,000 and < 240,000

All

8.6 EER

2.9 COP

 

Table D-2
Standards for Dehumidifiers

Product capacity (pint/day)

Minimum energy factor (liters/kWh)

Effective October 1, 2007

Effective October 1, 2012

25.00 or less

1.00

1.35

25.01 – 35.00

1.20

1.35

35.01 – 45.00

1.30

1.50

45.01 – 54.00

1.30

1.60

54.01 – 74.99

1.50

1.70

75.00 or more

2.25

2.50

 

Table E-2
Standards for Gas Wall Furnaces, Floor Furnaces, and Room Heaters

Appliance

Design
Type

Capacity
(Btu per hour)

Minimum AFUE (%)

Effective Before
April 16, 2013

Effective On or
After April 16, 2013

Wall furnace

Fan

< 42,000

73

75

Wall furnace

Fan

> 42,000

74

76

Wall furnace

Gravity

< 10,000

59

65

Wall furnace

Gravity

> 10,000 and < 12,000

60

Wall furnace

Gravity

> 12,000 and < 15,000

61

Wall furnace

Gravity

> 15,000 and < 19,000

62

Wall furnace

Gravity

> 19,000 and < 27,000

63

Wall furnace

Gravity

> 27,000 and < 46,000

64

66

Wall furnace

Gravity

> 46,000

65

67

Floor furnace

All

< 37,000

56

57

Floor furnace

All

> 37,000

57

58

Room heater

All

< 18,000

57

61

Room heater

All

> 18,000 and < 20,000

58

Room heater

All

> 20,000 and < 27,000

63

66

Room heater

All

> 27,000 and < 46,000

64

67

Room heater

All

> 46,000

65

68

 

Table E-3
Standards for Gas- and Oil-Fired Central Boilers
< 300,000 Btu/hour Input and Electric Residential Boilers

Appliance

Minimum AFUE (%)

Effective
January 1, 1992

Effective
September 1, 2012

Gas steam boilers with single phase electrical supply

75

80 ¹

Gas hot ‘water boilers with single phase electrical supply

80

82 ¹,²

Oil steam ‘boilers with single phase electrical supply

—

82

Oil hot water boilers with single phase electrical supply

—

84 ²

Electric steam residential boilers

—

NONE

Electric hot water residential boilers

 

NONE ²

All other boilers with single phase electrical supply

80

—

Gas ‘packaged boilers

---

---

Oil packaged boilers

---

---

¹ No constant burning pilot light design standard effective September 1, 2012.
² Automatic means for adjusting temperature design standard effective September 1, 2012.
(Boilers equipped with tankless domestic water heating coils do not need to comply with this requirement.)

 

Table E-5
Standards for Commercial Gas- and Oil-Fired Central Furnaces

Appliance

Rated Input (Btu/hr)

Minimum Thermal ‘Efficiency

Gas central furnaces

> 225,000

80

Oil central furnaces

> 225,000

81

 

Table F-2
Standards for Large Water Heaters Effective October 29, 2003

Appliance

Input to Volume Ratio

Size (Volume)

Minimum Thermal ‘Efficiency (%)

Maximum Standby Loss¹,²

Gas storage water heaters

< 4,000 Btu/hr/gal

Any

80

Q/800 + 110(Vr)1/2 Btu/hr

Gas instantaneous water heaters

< 4,000 Btu/hr/gal

< 10 gal

80

–

> 10 gal

80

Q/800 + 110(Vr)1/2 Btu/hr

Gas hot water supply boilers

< 4,000 Btu/hr/gal

< 10 gal

80

–

> 10 gal

80

Q/800 + 110(Vr)1/2 Btu/hr

Oil storage water heaters

< 4,000 Btu/hr/gal

any

78

Q/800 + 110(Vr)1/2 Btu/hr

Oil instantaneous water heaters

< 4,000 Btu/hr/gal

< 10 gal

80

–

> 10 gal

78

Q/800 + 110(Vr)1/2 Btu/hr

Oil hot water supply boilers

< 4,000 Btu/hr/gal

< 10 gal

80

–

> 10 gal

78

Q/800 + 110(Vr)1/2 Btu/hr

Electric storage water heaters

< 4,000 Btu/hr/gal

Any

–

0.3 + 27/Vm %/hr

¹ Standby loss is based on a 70°F temperature difference between stored water and ambient requirements. In the standby loss equations, Vr is the rated volume in gallons, Vm is the measured volume in gallons, and
 Q is the nameplate input rate in Btu/hr.
² Water heaters and hot water supply boilers having more than 140 gallons of storage capacity are not required to meet the standby loss requirement if the tank surface is thermally insulated to R‐ 12.5, if a standing pilot light is not installed, and for gas‐ or oil‐fired storage water heaters, there is a flue damper or fan‐assisted combustion.

 

Table F-3
Standards for Small Federally-Regulated Water Heaters

Appliance

Rated Storage Volume (gallons)

Minimum Energy Factor

Effective April 16, 2015

‘Gas-fired storage-type water heaters

≤ 55

0.675−(0.0015 × V)

> 55

0.8012−(0.00078 × V)

Oil‐fired water heaters (storage and instantaneous)

Any

0.68 – (.0019 x V)

Electric ‘storage water heaters (excluding tabletop water heaters)

≤ 55

0.960−(0.0003 × V)

> 55

2.057−(0.00113 × V)

Electric tabletop water heaters

Any

0.93 – (0.00132 x V)

Gas‐fired instantaneous water heaters

Any

0.82 – (0.0019 x V)

Electric instantaneous water heaters (excluding tabletop water heaters)

Any

0.93 – (0.00132 x V)

Heat pump water heaters

Any

0.97 – (.00132 x V)

V = Rated storage volume in gallons.

 

Table H-1
Standards for Plumbing Fittings

Appliance

Maximum Flow Rate

Wash fountains

2.2xrim space (inches)/20 gpm at 60psi

Metering ‘faucets

0.25 gallons/cycle 1, 2

Metering faucets for wash fountains

0.25xrim space (inches)/20 gpm at 60 psi 1, 2

 

1Sprayheads with independently‐controlled orifices and metered controls. The maximum flow rate of each orifice that delivers a pre‐set volume of water before gradually shutting itself off shall not exceed the maximum flow rate for a metering faucet.

2Sprayheads with collectively‐controlled orifices and metered controls. The maximum flow rate of a sprayhead that delivers a pre‐set volume of water before gradually shutting itself off shall be the product of (a) the maximum flow rate for a metering ‘faucet and (b) the number of component lavatories (rim space of the lavatory in inches (millimeters) divided by 20 inches (508 millimeters)).

 

Table J-1
Standards for Fluorescent Lamp Ballasts and Replacement Fluorescent Lamp Ballasts

Application for Operation of

Ballast Input Voltage

Total Nominal Lamp Watts

Minimum Ballast Efficacy Factor

one F40T12 lamp

120 or 277

40

2.29¹

1.805²

two F40T12 lamps

120

80

1.17¹

1.060²

277

80

1.17¹

1.050²

two F96T12 lamps

120 or 277

150

0.63¹

0.570²

two F96T12HO lamps

120 or 277

220

0.39¹

0.390²

¹ For fluorescent lamp ballasts manufactured on or after April 1, 2005; sold by the manufacturer on or after July 1, 2005; or incorporated into a luminaire by a luminaire manufacturer on or after April 1, 2006.
² For fluorescent lamp ballasts designed, marked, and shipped as replacement ballasts.

 

Table J-2
Standards for Fluorescent Lamp Ballasts1

Application for Operation of

Ballast Input Voltage

Total Nominal Lamp Watts

Minimum Ballast Efficacy Factor

one F34T12 lamp

120 or 277

34

2.61

two F34T12 lamps

120 or 277

68

1.35

two F96T12/ES lamps

120 or 277

120

0.77

two F96T12HO/ES lamps

120 or 277

190

0.42

¹ For fluorescent lamp ballasts manufactured on or after July 1, 2009; sold by the manufacturer on or after October 1, 2009; or fluorescent lamp ballasts incorporated into a luminaire by a luminaire manufacturer on or after July 1, 2010.

 

Table K-2
Standards for Federally-Regulated General Service Fluorescent Lamps
Manufactured Before July 15, 2012

Appliance

Nominal ‘Lamp Wattage

Minimum Color Rendering Index (CRI)

Minimum Average Lamp Efficacy (LPW)

4‐foot medium bi‐pin lamps

> 35

69

75.0

≤ 35

45

75.0

2‐foot U‐shaped lamps

> 35

69

68.0

≤ 35

45

64.0

8-foot slimline lamps

> 65

69

80.0

≤ 65

45

80.0

8‐foot high output lamps

> 100

69

80.0

≤ 100

45

80.0

 

Table K-3
Standards for Federally-Regulated General Service Fluorescent Lamps
 Manufactured On or After July 15, 2012

Appliance

Correlated Color Temperature

Minimum Average Lamp Efficacy (LPW)

4‐foot medium bipin lamps

≤ 4,500K

89

> 4,500K and ≤ 7,000K

88

2‐foot U‐shaped lamps

≤ 4,500K

84

> 4,500K and ≤ 7,000K

81

8-foot slimline lamps

≤ 4,500K

97

> 4,500K and ≤ 7,000K

93

8‐foot high output lamps

≤ 4,500K

92

> 4,500K and ≤ 7,000K

88

4‐foot miniature bipin standard output

≤ 4,500K

86

> 4,500K and ≤ 7,000K

81

4‐foot miniature bipin high output

≤ 4,500K

76

> 4,500K and ≤ 7,000K

72

 

Table K-4
Standards for Federally-Regulated Incandescent Reflector Lamps
 Manufactured Before July 15, 2012

Nominal ‘Lamp Wattage

Minimum Average ‘Lamp Efficacy (LPW)

40‐50

10.5

51‐66

11.0

67‐85

12.5

86‐115

14.0

116‐155

14.5

156‐205

15.0

 

Table K-5
Standards for Federally-Regulated Incandescent Reflector Lamps
Manufactured On or After July 15, 2012

‘Lamp Spectrum

Lamp Diameter (inches)

Rated Voltage

Minimum Average ‘Lamp Efficacy (LPW)1

Standard Spectrum

> 2.5

≥ 125

6.8 x P0.27

< 125

5.9 x P0.27

≤ 2.5

≥ 125

5.7 x P0.27

< 125

5.0 x P0.27

Modified Spectrum

> 2.5

≥ 125

5.8 x P0.27

< 125

5.0 x P0.27

≤ 2.5

≥ 125

4.9 x P0.27

< 125

4.2 x P0.27

1P = Rated Lamp Wattage, in Watts

 

Table K-6
Standards for Medium Base Compact Fluorescent Lamps

Factor

Requirements

‘Lamp Power (Watts) and Configuration¹

Minimum Efficacy: lumens/watt (Based upon initial lumen data)²

Bare Lamp:
Lamp Power < 15
Lamp Power ≥ 15


45.0
60.0

Covered Lamp (no reflector)
Lamp Power < 15
15 ≥ Lamp Power < 19 19 ≥ Lamp Power < 25 Lamp Power ≥ 25


40.0
48.0
50.0
55.0

1,000‐hour Lumen Maintenance

The average of at least 5 lamps must be a minimum 90% of initial (100‐ hour) lumen output @ 1,000 hours of rated life.

Lumen Maintenance

80% of initial (100‐hour) rating at 40 percent of rated life (per ANSI C78.5 Clause 4.10).

Rapid ‘Cycle Stress Test

Per ANSI C78.5 and IESNA LM‐65 (Clauses 2, 3, 5, and 6)
Exception: ‘Cycle times must be 5 minutes on, 5 minutes off. Lamp will be cycled once for every two hours of rated life. At least 5 lamps must meet or exceed the minimum number of ‘cycles.

Average Rated Lamp Life

≥ 6,000 hours as declared by the manufacturer on the packaging. 80% of rated life, statistical methods may be used to confirm lifetime claims based on sampling performance.

¹ Take performance and electrical requirements at the end of the 100‐hour aging period according to ANSI Standard C78.5. The lamp efficacy shall be the average of the lesser of the lumens per watt measured in the base up and/or other specified positions. Use wattages placed on packaging to select proper specification efficacy in this table, not measured wattage. Labeled wattages are for reference only.
² Efficacies are based on measured values for lumens and wattages from pertinent test data. Wattages and lumens placed on packages may not be used in calculation and are not governed by this specification. For multi‐level or dimmable systems, measurements shall be at the highest setting. Acceptable measurement error is ±3%.

 

Table K-7
Standards for Federally-Regulated General Service Incandescent Lamps

Rated Lumen Ranges

Maximum Rate Wattage

Minimum Rate Lifetime

Effective Date

1490‐2600

72

1,000 hours

January 1, 2012

1050 – 1489

53

1,000 hours

January 1, 2013

750 – 1049

43

1,000 hours

January 1, 2014

310 – 749

29

1,000 hours

January 1, 2014

 

Table K-8
Standards for Federally-Regulated Modified Spectrum General Service Incandescent Lamps

Rated Lumen Ranges

Maximum Rate Wattage

Minimum Rate Lifetime

Effective Date

1118‐1950

72

1,000 hours

January 1, 2012

788‐1117

53

1,000 hours

January 1, 2013

563‐787

43

1,000 hours

January 1, 2014

232‐562

29

1,000 hours

January 1, 2014

 

Table K-9
Standards for Federally Regulated Candelabra Base
Incandescent Lamps and Intermediate Base Incandescent Lamps

Lamp Base Type

Maximum Rated Wattage

Candelabra

60

Intermediate

40

 

Table M-1
Standards for Traffic Signals for Vehicle and Pedestrian Control

Appliance

Maximum Wattage (at 74°C)

Nominal Wattage (at 25°C)

Traffic Signal Module Type:

 

12‐inch; Red Ball

17

11

8‐inch; Red Ball

13

8

12‐inch; Red Arrow

12

9

12‐inch; Green Ball

15

15

8‐inch; Green Ball

12

12

12‐inch; Green Arrow

11

11

Pedestrian Module Type:

 

Combination Walking Man/Hand

16

13

Walking Man

12

9

Orange Hand

16

13

 

Table O
Standards for Dishwashers

Appliance

Effective January 1, 2010

Effective May 30, 2013

Maximum ‘Energy Use (kWh/year)

Maximum ‘Water Use (gallons/cycle)

Maximum ‘Energy Use (kWh/year)

Maximum ‘Water Use (gallons/cycle)

Compact ‘dishwashers

260

4.5

222

3.5

Standard dishwashers

355

6.5

307

5.0

 

Table P-1
Standards for Residential Clothes Washers Manufactured
 On or After January 1, 2007 and Manufactured Before March 7, 2015

Appliance

Minimum Modified ‘Energy Factor Effective January 1, 2007

Maximum Water Factor Effective January 1, 2011

Top‐loading compact clothes washers

0.65

‐‐

Top‐loading standard clothes washers

1.26

9.5

Top‐loading, semi‐automatic

N/A¹

‐‐

Front‐loading ‘clothes washers

1.26

9.5

Suds‐saving

N/A¹

‐‐

¹ Must have an unheated rinse water option.

 

Table P-2
Standards for Residential Clothes Washers Manufactured On or After March 7, 2015

Appliance

Minimum Integrated
Modified ‘Energy Factor

Maximum Integrated
Water Factor

March 7, 2015

January1, 2018

March 7, 2015

January1, 2018

Top‐loading, Compact

0.86

1.15

14.4

12.0

Top‐loading, Standard

1.29

1.57

8.4

6.5

Front‐loading, Compact

1.13

1.13

8.3

8.3

Front‐loading, Standard

1.84

1.84

4.7

4.7

 

Table P-3
Standards for Commercial Clothes Washers

Appliance

Minimum Modified ‘Energy Factor

Maximum Water Factor

Effective January 8, 2013

Top-loading clothes washer

1.6

8.5

Front-loading clothes washer

2.00

5.5

 

Modified Energy Factor (MEF) Cu. ft./kWh/cycle

Integrated Water factor (IWF) gal./cu./cycle

Effective January 8, 2013

Top-loading clothes washer

1.35

8.8

Front-loading clothes washer

2.00

4.1

 

Table Q-1
Standards for Clothes Dryers Manufactured On or After
May 14, 1994 and Manufactured Before January 1, 2015

Appliance

Minimum Energy Factor (lbs/kWh)

Electric, standard clothes dryers

3.01

Electric, compact, 120 volt clothes dryers

3.13

Electric, compact, 240 volt clothes dryers

2.90

Gas clothes dryers

2.67

 

Table S-1 Standards for Electric Motors

Motor Horsepower/Standard Kilowatt Equivalent

Minimum Nominal Full-Load Efficiency

Open Motors

Enclosed Motors

6 poles

4 poles

2 poles

6 poles

4 poles

2 poles

1/0.75

80.0

82.5

. . .

80.0

82.5

75.5

1.5/1.1

84.0

84.0

82.5

85.5

84.0

82.5

2/1.5

85.5

84.0

84.0

86.5

84.0

84.0

3/2.2

86.5

86.5

84.0

87.5

87.5

85.5

5/3.7

87.5

87.5

85.5

87.5

87.5

87.5

7.5/5.5

88.5

88.5

87.5

89.5

89.5

88.5

10/7.5

90.2

89.5

88.5

89.5

89.5

89.5

15/11

90.2

91.0

89.5

90.2

91.0

90.2

20/15

91.0

91.0

90.2

90.2

91.0

90.2

25/18.5

91.7

91.7

91.0

91.7

92.4

91.0

30/22

92.4

92.4

91.0

91.7

92.4

91.0

40/30

93.0

93.0

91.7

93.0

93.0

91.7

50/37

93.0

93.0

92.4

93.0

93.0

92.4

60/45

93.6

93.6

93.0

93.6

93.6

93.0

75/55

93.6

94.1

93.0

93.6

94.1

93.0

100/75

94.1

94.1

93.0

94.1

94.5

93.6

125/90

94.1

94.5

93.6

94.1

94.5

94.5

150/110

94.5

95.0

93.6

95.0

95.0

94.5

200/150

94.5

95.0

94.5

95.0

95.0

95.0

 

Table T-3 Standards for Low-Voltage Dry-Type Distribution Transformers

Single phase

 

 

Three phase

kVA

Efficiency (%)¹

 

kVA

 

Efficiency (%)¹

 

Effective January 1,

2007

Effective January 1,

2016

 

Effective January 1,

2007

Effective January 1,

2016

15

97.7

97.70

15

97.0

97.89

25

98.0

98.00

30

97.5

98.23

37.5

98.2

98.20

45

97.7

98.40

50

98.3

98.30

75

98.0

98.60

75

98.5

98.50

112.5

98.2

98.74

100

98.6

98.60

150

98.3

98.83

167

98.7

98.70

225

98.5

98.94

250

98.8

98.80

300

98.6

99.02

333

98.9

98.90

500

98.7

99.14

 

 

 

750

98.8

99.23

 

 

 

1000

98.9

99.28

¹ Efficiencies are determined at the following reference conditions:

(1) for no-load losses, at the temperature of 20°C, and (2) for load-losses, at the temperature of 75°C and 35 percent of nameplate load.

(Source: Table 4–2 of NEMA Standard TP–1–2002, “Guide for Determining Energy Efficiency for Distribution Transformers.”)

 

Table T-4 Standards for Liquid-Immersed Distribution Transformers

Single phase

Three phase

kVA

Efficiency (%)¹

kVA

Efficiency (%)¹

 

Effective January 1,

2007

Effective January 1,

2016

 

Effective January 1,

2007

Effective January 1,

2016

10

98.62

15

98.36

98.65

15

98.76

30

98.62

98.83

25

98.91

45

98.76

98.92

37.5

99.01

75

98.91

99.03

50

99.08

112.5

99.01

99.11

75

99.17

150

99.08

99.16

100

99.23

225

99.17

99.23

167

99.25

300

99.23

99.27

250

99.32

500

99.25

99.35

333

99.36

750

99.32

99.40

500

99.42

1000

99.36

99.43

667

99.46

1500

99.42

99.48

833

99.49

2000

99.46

99.51

 

 

2500

99.49

99.53

¹ Note: All efficiency values are at 50 percent of nameplate-rated load, determined when tested according to the test procedure in Section 1604(t).

 

Table T-5 Standards for Medium-Voltage Dry-Type Distribution Transformers Manufactured On or After January 1, 2010 and Before January 1, 2016

Single phase

Three phase

BIL kVA

20‐45 kV Efficiency¹ (%)

46‐95 kV Efficiency¹ (%)

≥ 96 kV Efficiency¹ (%)

BIL kVA

20‐45 kV Efficiency¹ (%)

46‐95 kV Efficiency¹ (%)

≥ 96 kV Efficiency¹ (%)

15

98.10

97.86

 

15

97.50

97.18

 

25

98.33

98.12

 

30

97.90

97.63

 

37.5

98.49

98.30

 

45

98.10

97.86

 

50

98.60

98.42

 

75

98.33

98.12

 

75

98.73

98.57

98.53

112.5

98.49

98.30

 

100

98.82

98.67

98.63

150

98.60

98.42

 

167

98.96

98.83

98.80

225

98.73

98.57

98.53

250

99.07

98.95

98.91

300

98.82

98.67

98.63

333

99.14

99.03

98.99

500

98.96

98.83

98.80

500

99.22

99.12

99.09

750

99.07

98.95

98.91

667

99.27

99.18

99.15

1000

99.14

99.03

98.99

833

99.31

99.23

99.20

1500

99.22

99.12

99.09

 

 

 

 

2000

99.27

99.18

99.15

 

 

 

 

2500

99.31

99.23

99.20

¹ All efficiency values are at 50 percent of nameplate rated load, determined when tested according to the test procedure in Section 1604(t).

 

Table T-6 Standards for Medium-Voltage Dry-Type Distribution Transformers
Manufactured On or After January 1, 2016

 

Single phase

Three phase

BIL kVA

20‐45 kV Efficiency¹ (%)

46‐95 kV Efficiency¹ (%)

≥ 96 kV Efficiency¹ (%)

BIL kVA

20‐45 kV Efficiency¹ (%)

46‐95 kV Efficiency¹ (%)

≥ 96 kV Efficiency¹ (%)

15

98.10

97.86

 

15

97.50

97.18

 

25

98.33

98.12

 

30

97.90

97.63

 

37.5

98.49

98.30

 

45

98.10

97.86

 

50

98.60

98.42

 

75

98.33

98.13

 

75

98.73

98.57

98.53

112.5

98.52

98.36

 

100

98.82

98.67

98.63

150

98.65

98.51

 

167

98.96

98.83

98.80

225

98.82

98.69

98.57

250

99.07

98.95

98.91

300

98.93

98.81

98.69

333

99.14

99.03

98.99

500

99.09

98.99

98.89

500

99.22

99.12

99.09

750

99.21

99.12

99.02

667

99.27

99.18

99.15

1000

99.28

99.20

99.11

833

99.31

99.23

99.20

1500

99.37

99.30

99.21

 

 

 

 

2000

99.43

99.36

99.28

 

 

 

 

2500

99.47

99.41

99.33

¹ All efficiency values are at 50 percent of nameplate rated load, determined when tested according to the test procedure in Section 1604(t).

 

Table U-1 Standards for Class A External Power Supplies That are Federally Regulated

Nameplate Output

Minimum Efficiency in Active Mode

(Decimal equivalent of a Percentage)

< 1 watt

0.5 * Nameplate Output

≥ 1 and ≤ 51 watts

0.09*Ln(Nameplate Output) + 0.5

> 51 watts

0.85

 

Maximum Energy Consumption in No-Load Mode

≤ 250 watts

0.5 watts

Where Ln (Nameplate Output) = Natural Logarithm of the nameplate output expressed in watts.

 

Table A-9 Standards for Wine Chillers

Appliance

Maximum Annual Energy Consumption (kWh)

Wine chillers with manual defrost

13.7V + 267

Wine chillers with automatic defrost

17.4V + 344

V = volume in ft³.

 

Table A-10 Standards for Freezers that are Consumer Products

Appliance

Maximum Annual Energy Consumption (kWh)

Upright Freezers with manual defrost

7.55AV + 258.3

Upright Freezers with automatic defrost

12.43AV + 326.1

Chest Freezers

9.88AV + 143.7

AV = adjusted total volume, expressed in ft³, which is 1.73 x freezer volume (ft³).

 

Table A-12 Standards for Refrigerated Canned and Bottled Beverage Vending Machines

Appliance

Doors

Maximum Daily Energy Consumption (kWh)

January 1, 2006

January 1, 2007

Refrigerated canned and bottled beverage vending machines when tested at 90° F ambient temperature except multi-package units

Not applicable

0.55(8.66 + (0.009 × C))

0.55(8.66 + (0.009 × C))

 

Table C-7 Standards for Ground Water-Source and Ground-Source Heat Pumps

Appliance

Rating Condition

Minimum Standard

Ground water-source heat pumps (cooling)

59°F entering water temperature

16.2 EER

Ground water-source heat pumps (heating)

50°F entering water temperature

3.6 COP

Ground-source heat pumps (cooling)

77°F entering brine temperature

13.4 EER

Ground-source heat pumps (heating)

32°F entering brine temperature

3.1 COP

 

Table C-8 Standards for Evaporatively Cooled Computer Room Air Conditioners

Appliance

Cooling Capacity (Btu/hr)

Minimum EER (Btu/watt‐hour)

Air‐Cooled Effective January 1, 2006

Water‐Cooled, Glycol‐Cooled, and Evaporatively‐Cooled Effective October 29, 2006

Computer room air conditioners

< 65,000

11.0

11.1

≥ 65,000 and < 135,000

10.4

10.5

≥ 135,000 and < 240,000

10.2

10.0

 

Table E-7 Standards for Boilers

Appliance

Output (Btu/hr)

Minimum AFUE %

Minimum Combustion Efficiency % *

Maximum Standby Loss (watts)

Gas steam boilers with 3-phase electrical supply

< 300,000

75

—

—

All other boilers with 3-phase electrical supply

< 300,000

80

—

—

Natural gas, non-packaged boilers

≥ 300,000

—

80

147

LPG Non-packaged boilers

≥ 300,000

—

80

352

Oil, non-packaged boilers

≥ 300,000

—

83

—

*At both maximum and minimum rated capacity, as provided and allowed by the controls.

 

Table E-8 Standards for Furnaces

Appliance

Application

Minimum Efficiency %

Central furnaces with 3-phase electrical supply < 225,000 Btu/hour

Mobile Home

75 AFUE

All others

78 AFUE or 80 Thermal Efficiency (at manufacturer’s option)

 

Table E-9 Standards for Duct Furnaces

Appliance

Fuel

Standards

Minimum Thermal Efficiency %¹

Maximum Energy Consumption during standby (watts)

At maximum rated capacity

At minimum rated capacity

Duct furnaces

Natural gas

80

75

10

Duct furnaces

LPG²

80

75

147

¹ As provided and allowed by the controls.

² Designed expressly for use with LPG.

 

Table F-4 Standards for Small Water Heaters that are Not Federally-Regulated Consumer Products

Appliance

Energy Source

Input Rating

Rated Storage Volume (gallons)

Minimum Energy Factor¹

Storage water heaters

Gas

≤ 75,000 Btu/hr

< 20

0.62 – (.0019 x V)

Storage water heaters

Gas

≤ 75,000 Btu/hr

> 100

0.62 – (.0019 x V)

Storage water heaters

Oil

≤ 105,000 Btu/hr

> 50

0.59 – (.0019 x V)

Storage water heaters

Electricity

≤ 12 kW

> 120

0.93 – (.00132 x V)

Instantaneous Water Heaters

Gas

≤ 50,000 Btu/hr

Any

0.62 – (.0019 x V)

Instantaneous Water Heaters

Gas

≤ 200,000 Btu/hr

≥ 2

0.62 – (.0019 x V)

Instantaneous Water Heaters

Oil

≤ 210,000 Btu/hr

Any

0.59 – (.0019 x V)

Instantaneous Water Heaters

Electricity

≤ 12 kW

Any

0.93 – (.00132 x V)

¹ Volume (V) = rated storage volume in gallons.

 

Table H-2 Standards for Tub Spout Diverters

Appliance

Testing Conditions

Maximum Leakage Rate

Tub spout diverters

When new

0.01 gpm

After 15,000 cycles of diverting

0.05 gpm

 

Table K-9 Standards for State-Regulated Incandescent Reflector Lamps

Rated Lamp Wattage

Minimum Average Lamp Efficacy (LPW)

40-50

10.5

51-66

11.0

67-85

12.5

86-115

14.0

116-155

14.5

156-205

15.0

 

Table K-10 Standards for State-Regulated General Service Incandescent Lamps -Tier I

Rated Lumen Ranges

Maximum Rated Wattage

Minimum Rated Lifetime

Effective Date

1490-2600 Lumens

72 watts

1,000 Hours

Jan, 1, 2011

1050-1489 Lumens

53 watts

1,000 Hours

Jan 1, 2012

750-1049 Lumens

43 watts

1,000 Hours

Jan 1, 2013

310-749 Lumens

29 watts

1,000 Hours

Jan 1, 2013

 

Table K-11 Standards for State-Regulated General Service Lamps -Tier II

Lumen Ranges

Minimum Lamp Efficacy

Minimum Rated Lifetime

Effective Date

All

45 lumens per watt

1,000 Hours

Jan, 1, 2018

 

Table K-12 Standards for State-Regulated Modified
Spectrum General Service Incandescent Lamps -Tier I

Rated Lumen Ranges

Maximum Rated Wattage

Minimum Rated Lifetime

Effective Date

1118-1950 Lumens

72 watts

1,000 Hours

Jan 1, 2011

788-1117 Lumens

53 watts

1,000 Hours

Jan 1, 2012

563-787 Lumens

43 watts

1,000 Hours

Jan 1, 2013

232-562 Lumens

29 watts

1,000 Hours

Jan 1, 2013

 

Table L-1 Ultrasound Maximum Decibel Values

Mid-frequency of Sound Pressure Third-Octave Band (in kHz)

Maximum db Level within third-Octave Band(in dB reference 20 micropascals)

Less than 20

80

20 or more to less than 25

105

25 or more to less than 31.5

110

31.5 or more

115

 

Table M-2 Standards for Traffic Signal Modules for Pedestrian
 Control Sold or Offered for Sale in California

Type

at 25°C (77°F)

At 74°C (165.2°F)

Hand or ‘Don’t Walk’ sign or countdown.

10 watts

12 watts

Walking Person or ‘Walk’ sign

9 watts

12 watts

 

Table N-1 Standards for Under-Cabinet Luminaires

Lamp Length

(inches)

Minimum Ballast Efficacy Factor (BEF) for one lamp

Minimum Ballast Efficacy Factor (BEF) for two lamps

≤29

4.70

2.80

>29 and ≤35

3.95

2.30

>35 and ≤41

3.40

1.90

>41 and ≤47

3.05

1.65

>47

2.80

1.45

 

Table N-2 Minimum Requirements for Portable LED Luminaires, and
Portable Luminaires with LED Light Engines with Integral Heat Sink

Criteria

Requirement

Light Output

≥ 200 lumens (initial)

Minimum LED Luminaire Efficacy

29 lumens/W

Minimum LED Light Engine Efficacy

40 lumens/W

Color Correlated Temperature (CCT)

2700 K through 5000 K

Minimum Color Rendering Index (CRI)

75

Power Factor (for luminaires labeled or sold for residential use)

≥ 0.70

 

Table U-2 Standards for State-Regulated External Power Supplies Effective January 1, 2007

for external power supplies used with laptop computers, mobile phones, printers, print
servers, canners, personal digital assistants (PDAs), and digital cameras, Effective July 1, 2007
 for external power supplies used with wireline telephones and all other applications.

Nameplate Output

Minimum Efficiency in Active Mode

0 to < 1 watt

0.49 * Nameplate Output

≥ 1 and ≤ 49 watts

0.09 * Ln(Nameplate Output) + 0.49

> 49 watts

0.84

 

Maximum Energy Consumption in No-Load Mode

0 to <10 watts

0.5 watts

≥ 10 to ≤ 250 watts

0.75 watts

Where Ln (Nameplate Output) = Natural Logarithm of the nameplate output expressed in watts.

 

Table U-3 Standards for State-Regulated External Power Supplies
Effective July 1, 2008

Nameplate Output

Minimum Efficiency in Active Mode

<1 watt

0.5 * Nameplate Output

≥ 1 and ≤ 51 watts

0.09*Ln(Nameplate Output) + 0.5

> 51 watts

0.85

 

Maximum Energy Consumption in No-Load Mode

Any output

0.5 watts

Where Ln (Nameplate Output) = Natural Logarithm of the nameplate output expressed in watts.

 

Table V-1 Standards for Consumer Audio and Video Equipment

Appliance Type

Effective Date

Maximum Power Usage (Watts)

Compact Audio Products

January 1, 2007

2 W in Audio standby-passive mode for those without a permanently illuminated clock display

4 W in Audio standby-passive mode for those with a permanently illuminated clock display

Digital Versatile Disc Players and Digital Versatile Disc Recorders

January 1, 2006

3 W in Video standby-passive mode

 

Table V-2 Standards for Televisions

Effective Date

Screen Size (area A in square inches)

Maximum TV Standby-passive Mode Power Usage (watts)

Maximum On Mode Power Usage (P in Watts)

Minimum Power Factor for (P ≥ 100W)

January 1, 2006

All

3 W

No standard

No standard

January 1, 2011*

A < 1400

1 W

P ≤ 0.20 x A + 32

0.9

January 1, 2013

A < 1400

1 W

P ≤ 0.12 x A + 25

0.9

 

Table W-1 Standards for Large Battery Charger Systems

Performance Parameter

Standard

Charge Return Factor (CRF)

100 percent, 80 percent Depth of discharge

CRF≤ 1.10

40 percent Depth of discharge

CRF ≤ 1.15

Power Conversion Efficiency

Greater than or equal to: 89 percent

Power Factor

Greater than or equal to: 0.90

Maintenance Mode Power (Eb = battery capacity of tested battery)

Less than or equal to: 10 + 0.0012Eb W

No Battery Mode Power

Less than or equal to: 10 W

 

Table W-2 Standards for Small Battery Charger Systems

Performance Parameter

Standard

Maximum 24 hour charge and maintenance energy (Wh)

(Eb = capacity of all batteries in ports and N = number of charger ports)

For Eb of 2.5 Wh or less:
16 × N

For Eb greater than 2.5 Wh and less than or equal to 100 Wh:
12 x N +1.6Eb

For Eb greater than 100 Wh and less than or equal to 1000 Wh:
22 x N+1.5Eb

For Eb greater than 1000 Wh:
36.4 x N +1.486Eb

Maintenance Mode Power and No Battery Mode Power (W)
(Eb = capacity of all batteries in ports and N = number of charger ports)

The sum of maintenance mode power and no battery mode power must be less than or equal to:

1x N+0.0021xEb