1.1   Appliances, Miscellaneous Energy Use and Internal Gains

Full details of the assumptions for lighting and appliance loads are found in the Codes and Standards Enhancement Initiative (CASE) Plug Loads and Lighting Modeling (Rubin 2016, see Appendix D).

 

1.1.1    Background

Rulesets for all plug loads (including appliances and miscellaneous electric loads (MELs)) and lighting loads were updated in 2016. The CASE report describes the methodology, data sources, and assumptions used to develop the rulesets. The updated methodology replaces the rulesets from the 2013 Residential Alternative Calculation Method (ACM) Reference Manual (ACM Reference Manual), which in turn referenced the 2008 California Home Energy Rating System (HERS) Technical Manual.

The rulesets were modified to reflect efficiency levels assuming 2017 federal code baseline or 2017 projected market average performance, depending on whether or not a product is regulated by federal energy efficiency standards. Miscellaneous loads were disaggregated so that the three largest loads in this group—televisions, set-top boxes, and computers and monitors—are modeled individually. The remaining miscellaneous loads are modeled in aggregate. Garage lighting is also disaggregated from interior lighting. Assumptions about how energy use scales with building size were updated for all plug load and lighting end uses.

Updated load profiles were proposed for the majority of the modeled plug load and lighting end uses. The proposed updates include revisions to both the hourly schedules and seasonal multipliers. The updated load profiles are based on the water heating models described in section 2.9 of the ACM Reference Manual for the applicable end uses and otherwise on recent submetering studies

.

1.1.2    Approach

Rulesets for all modeled end uses reflect the estimated energy consumption of those devices in new homes built during the 2016 Title 24 Code Cycle. The plug load rulesets estimate annual energy consumption (AEC) as a function of number of bedrooms (BRperUnit) and the lighting rulesets estimate AEC as a function of conditioned floor area (CFAperUnit). The relationship between AEC and BRperUnit for dishwashers, clothes washers, and clothes dryers was based on the usage assumptions in the water heating model. The relationship between all other plug load AEC and BRperUnit was generally derived from the 2009 Residential Appliance Saturation Survey (RASS), through a statistical and engineering analysis that applied modern efficiency assumptions to estimate what the AEC of plug loads within homes included in the 2009 RASS would be if they were built during the 2016 Title 24 code cycle. The relationship between lighting AEC and CFAperUnit was derived using a similar analysis completed on the RASS data but using data from the 2012 California Lighting and Appliance Saturation Survey.

With additional user inputs, the default AEC equations for primary refrigerators, clothes washers, and clothes dryers can be modified to reflect the efficiency of the devices that are actually installed in the building. That is, the modeled energy use can be adjusted downward if more efficient devices are installed (the software tool can also adjust energy use upward if devices are less efficient).

Updated load profiles are derived from the following data sources:

•      Dishwashers, clothes washers, and clothes dryers: updated to be consistent with the usage patterns assumed by water heating models described in section 2.9 of the ACM Reference Manual.

•      Ovens, cooktops, and televisions: based on data from the Phased Deep Retrofit (PDR) study conducted by the Florida Solar Energy Center (FSEC), which submetered 60 Florida homes in 2012.

•      Set-top boxes, computers, and monitors: based on the Northwest Energy Efficiency Alliance (NEEA) Residential Building Stock Assessment (RBSA), released in 2014. This study monitored 100 homes in the Pacific Northwest over the course of one year, submetering major end uses at 15 minute intervals.

•      Exterior lighting: the proposed hourly schedule for exterior lighting is derived from the NEEA RBSA light logging data; the proposed exterior lighting seasonal multipliers are no longer constant, but instead equivalent to the interior and garage seasonal multipliers.

Load profiles for interior lighting, garage lighting, and residual MELs were not updated in 2016. The current hourly schedules for interior lighting are based on the 1999 Heschong Mahone Group (HMG) study “Lighting Efficiency Technology Report: California Baseline.” The current hourly schedule for residual MELs is derived from the 2008 Building America House Simulation Protocol, which in turn relied on data from a 1989 Pacific Northwest submetering study conducted by the End-Use Load and Consumer Assessment Program (ELCAP).

Refrigerators and freezers use PDR data to adjust estimated energy use on an hourly basis depending on the modeled indoor temperature (using the Title 24 compliance software) in the space where the refrigerator is installed.

 

1.1.3    Problems

The plug load and lighting rulesets have some limitations. The rulesets generally do not account for differences in energy use patterns between single-family and multi-family housing. For example, they do not account for the energy use of laundry equipment in multi-family residences that is installed in common areas—only laundry equipment in the dwelling units.

The plug load and lighting rulesets were developed to apply to new homes built during the 2016 Title 24 Code Cycle, and thus should not be used for estimating energy use for existing homes.

 

1.1.4    Inputs

1.1.4.1        AEC Inputs and Algorithms

Table-1 summarizes the user inputs that determine the plug load and lighting annual energy consumption (AEC) estimates. The variable ‘BRperUnit’ refers to the number of bedrooms in a single-family home or the number of bedrooms in each dwelling unit of a multi-family building. Similarly, ‘CFAperUnit’ refers to the conditioned floor area per dwelling unit. AEC equations are to be applied to each dwelling unit within a multi-family building, not the building as a whole. Users also specify the zone where certain major appliances are located; however, this affects the modeled internal gains from equipment and lighting, not their estimated energy use of the plug load or lighting load and is therefore not included in the table below. The Optional inputs are not implemented in CBECC-Res 2016.2, but may be allowed in future releases.

Table 1: User Inputs Affecting Estimated Plug Load and Lighting Energy Use

-     -  

-     -  

-     -  

-     -  

End Use

User Inputs that Determine Estimated Energy Use

Notes

Primary Refrigerator/ Freezer

BRperUnit

Optional: rated annual kWh usage from the Energy Guide label of the installed device

Default kWh can be overridden with the rated annual kWh usage input on the Energy Guide label; however, there is a maximum allowable kWh credit dependent on BRperUnit.

Energy use adjusted on an hourly basis depending on the indoor temperature in the kitchen simulated in the software.

Non-Primary Refrigerators and Separate Freezers

BRperUnit

Single-family or multi-family housing

Assumed to be installed in the garage in new, single-family homes.

Assumed to be absent in multi-family dwelling units.

Dishwasher

BRperUnit

Presence of device

Single-family or multi-family

Ruleset estimates machine energy use only.

Energy use is only included if user indicates the device will be present.

Assumed different usage patterns in single family and multi-family when developing algorithms.

 

Clothes Washer

BRperUnit

Presence of device

Single-family or multi-family

Optional: whether installed device will comply with the 2015 federal efficiency standards (credit for installing new or nearly-new device)

Ruleset estimates machine energy use only.

Energy use is only included if user indicates the device will be present.

Assumed different usage patterns in single family and multi-family when developing algorithms.

Default energy use can be reduced if the user specifies the device will meets the 2015 federal standard, which can be determined by looking up the model on the California Appliance Efficiency Database.

Clothes Dryer

BRperUnit

Presence of device

Fuel type (natural gas, propane, or electric)

Single-family or multi-family

Optional: percent remaining moisture content (RMC) of the clothes washer

Energy use is only included if user indicates the device will be present.

User can select fuel type. If user indicates natural gas is available at the site (see Section 2.2.10 of RACM), then the default fuel type is natural gas. If user indicates that natural gas is not available at the site then the default fuel type is electric. User cannot select natural gas as the fuel type if natural gas is not available at the site.

Default energy use can be reduced if the user specifies that the installed clothes washer has a rated RMC of less than 50 percent.

Oven

BRperUnit

Presence of device

Fuel type (natural gas, propane, or electric)

Energy use is only included if user indicates the device will be present.

User can select fuel type, but default assumption is natural gas if user indicates that natural gas is available on-site and electric if user indicates natural gas is not available on-site

Cooktop

 

 

Televisions

BRperUnit

 

Set-Top Boxes

Computers and Monitors
Residual MELs
Interior Lighting

CFAperUnit

 

Exterior Lighting

Garage Lighting

CFAperUnit

Presence of garage

Energy use is only included if user indicates there is a garage present.

Garage lighting is assigned to multi-family buildings if there is at least once garage present.

Carport lighting is covered under the exterior lighting ruleset.

Table 2 summarizes the proposed AEC algorithms for plug load and lighting. These linear equations take the following general form where the homes size metric is BRperUnit for plug loads and CFAperUnit for lighting:

 

Where:  y = Estimated AEC measured in kWh/yr or therms/yr

            m = how AEC changes with home size

            x = home size as measured in BRperUnit for plug loads or CFAperUnit for lighting

            b = minimum energy use (energy use at y-intercept)

 

BR-based equations are capped at 7 bedrooms, meaning that units with eight or more bedrooms have the same estimated AEC as a 7-bedroom unit. CFA-based equations are capped at 4,150 square feet. For those end uses that list ‘presence of device’ as a user input in Table 2, the AEC equation is only applied if the device is present. Similarly, for the AEC equations for end uses that can be gas or electric are only applied according to the user-specified fuel type. Gas algorithms apply to devices that use natural gas or propane.

Table 2: Algorithms for Plug Load and Lighting Annual Energy Use

End Use

Standard Design Fuel Type

kWh or therms

Intercept

Slope

Per-Unit

BR or CFA

Primary Refrigerator/Freezer

Electricity

kWh

454

37.0

BR

Non-Primary Refrigerators and Separate Freezers

(Single-Family only)

Electricity

kWh

0

71.0

BR

Oven

Electricity

kWh

138

16

BR

Oven

Gas

therms

6.0

0.95

BR

Oven

Gas

kWh

41

4.79

BR

Cooktop

Electricity

kWh

84

5.68

BR

Cooktop

Gas

therms

5.0

0.30

BR

Cooktop

Gas

kWh

0

0

BR

Televisions

Electricity

kWh

265

31.8

BR

Set-Top Boxes

Electricity

kWh

76

59.4

BR

Computers and Monitors

Electricity

kWh

79

55.4

BR

Residual MELs

Electricity

kWh

672

235

BR

Interior Lighting

Electricity

kWh

100

0.1775

CFA

Exterior Lighting

Electricity

kWh

8.0

0.0532

CFA

Garage Lighting

Electricity

kWh

20

0.0063

CFA

 

Table 3 and Table 4summarize the AEC algorithms for dishwashers, clothes washers and clothes dryers. These rulesets only include machine energy use from dishwashers and clothes washers. Energy use for water heating is accounted for in the water heating model.

Table 3: Single-Family Residence Algorithms for Dishwasher, Clothes Washer, and Clothes Dryer Annual Energy Use

BRperUnit

Dishwashers (kWh/yr)

Clothes Washers (kWh/yr)

Electric Clothes Dryers (kWh/yr)

Natural Gas Clothes Dryers

Natural Gas Use (therms/yr)

Electricity Use (kWh/yr)

0

                83

                84

634

22

32

1

                83

                84

634

22

32

2

                91

                85

636

22

32

3

                100

                99

748

26

37

4

                99

                101

758

27

38

5+

                119

                227

877

31

44

 

Table 4: Multi-Family Dwelling Unit Algorithms for Dishwasher, Clothes Washer, and Clothes Dryer Annual Energy Use

BRperUnit

Dishwashers (kWh/yr)

Clothes Washers (kWh/yr)

Electric Clothes Dryer (kWh/yr)

Gas Clothes Dryers

Natural Gas Usage (therms/yr)

Electricity Usage (kWh/yr)

0

56

                66

496

17

25

1

68

                70

527

19

26

2

96

                99

745

26

37

3

94

                97

733

26

37

4

121

                118

885

31

44

5+

114

                107

805

28

40

1.1.4.2        AEC Algorithms for High-Efficiency Appliances

As indicated in Table 5, if allowed in the software, users could override the default AEC rulesets for the primary refrigerator, clothes washer and clothes dryer if the software user has additional information about the device that will be installed.

For the primary refrigerator, the default AEC ruleset could be replaced with the rated AEC listed on the refrigerator’s Energy Guide label. If using this option, the user will input AEC measured in kWh per year, and that value will replace the AEC value for the primary refrigerator calculated using the equation below. The default AEC of the primary refrigerator cannot be adjusted below a certain value, which is dependent on BRperUnit as described in the following equation:

Users could reduce the estimated primary refrigerator AEC to this value, but no lower.

Table 5: Minimum primary refrigerator AEC that builders may claim by BRperUnit

BRperUnit

Default Primary Refrigerator AEC (kWh/yr)

Minimum Allowable Primary Refrigerator AEC (kWh/yr)

0

470

291

1

496

299

2

523

308

3

550

316

4

577

325

5

603

333

6

630

341

7+

657

350

 

For clothes washers, if allowed in the software, the user could specify that the installed clothes washer meets the 2015 federal standards (as documented on the CEC Appliance Efficiency Database). This effectively provides credit if the clothes washer is new or nearly new. Table 6 presents the AEC values used if the washer is compliant with the 2015 federal standards.

Table 6: Minimum allowable high-efficiency AEC for clothes washers

 

BRperUnit

Single Family

Multi-Family

Default AEC (kWh/yr)

High-Efficiency Clothes Washer AEC1 (kWh/yr)

Default AEC

(kWh/yr)

High-Efficiency Clothes Washer AEC1 (kWh/yr)

0

84

68

66

53

1

84

68

70

57

2

85

68

99

80

3

100

80

98

79

4

101

81

118

95

5+

117

94

107

86

1Applicable to clothes washers that meet the 2015 federal efficiency standards

 

For clothes dryers, if allowed in the software, the user could specify the percent remaining moisture content (RMC) of the installed clothes washer (as documented on the CEC Appliance Efficiency Database) to override the default clothes dryer AEC ruleset. The RMC-adjusted clothes dryer AEC should be calculated using the equations provided below. For natural gas dryers the RMC-adjusted AEC modifies natural gas use but does not impact electricity use.

 

Electric Dryer: RMC-adjusted AEC (kWh/yr)

 

 

Gas Dryer: RMC-adjusted AEC (therms/yr)

 

 

Table 7: Annual clothes dryer cycles estimated based on BrperUnit

BRperUnit

Dishwasher Cycles Per Year

Single-Family

Multi-Family

0

290

227

1

290

241

2

291

341

3

342

335

4

346

405

5+

401

368

 

1.1.4.3        Load Profiles

Dishwashers and clothes washers loads are specified in the water heating load profiles. Clothes dryers have the same usage assumptions as clothes washers, but shifted one hour later.

The estimated energy use for refrigerators is adjusted for each hour of the year depending on the simulated indoor temperature in the thermal zone where the refrigerator or freezer is installed (user input).Multi-family housing is assumed to have no energy use for non-primary refrigerators or separate freezers.

The following tables summarize the hourly load profiles and seasonal multipliers for the remaining plug load and lighting end uses.

Table 8: Hourly Multiplier – Weekdays

Hour

Oven and Cooktop

Televisions

Set-Top Boxes

Computers and Monitors

Residual MELs

Interior and Garage Lighting

Exterior Lighting

1

0.005

0.035

0.040

0.036

0.037

0.023

0.046

2

0.004

0.026

0.040

0.033

0.035

0.019

0.046

3

0.004

0.023

0.040

0.032

0.034

0.015

0.046

4

0.004

0.022

0.040

0.032

0.034

0.017

0.046

5

0.004

0.021

0.040

0.031

0.032

0.021

0.046

6

0.014

0.021

0.040

0.032

0.036

0.031

0.037

7

0.019

0.025

0.040

0.034

0.042

0.042

0.035

8

0.025

0.032

0.041

0.036

0.044

0.041

0.034

9

0.026

0.038

0.040

0.039

0.037

0.034

0.033

10

0.022

0.040

0.040

0.043

0.032

0.029

0.028

11

0.021

0.038

0.040

0.045

0.033

0.027

0.022

12

0.029

0.038

0.040

0.045

0.033

0.025

0.015

13

0.035

0.041

0.040

0.046

0.032

0.021

0.012

14

0.032

0.042

0.040

0.046

0.033

0.021

0.011

15

0.034

0.042

0.041

0.046

0.035

0.021

0.011

16

0.052

0.041

0.041

0.047

0.037

0.026

0.012

17

0.115

0.044

0.042

0.048

0.044

0.031

0.019

18

0.193

0.049

0.043

0.049

0.053

0.044

0.037

19

0.180

0.056

0.044

0.049

0.058

0.084

0.049

20

0.098

0.064

0.045

0.049

0.060

0.117

0.065

21

0.042

0.070

0.046

0.049

0.062

0.113

0.091

22

0.020

0.074

0.047

0.048

0.060

0.096

0.105

23

0.012

0.067

0.045

0.044

0.052

0.063

0.091

24

0.010

0.051

0.045

0.041

0.045

0.039

0.063

 

Table 9: Hourly Multiplier – Weekends

Hour

Oven and Cooktop

Televisions

Set-Top Boxes

Computers and Monitors

Residual MELs

Interior and Garage Lighting

Exterior Lighting

1

0.005

.035

0.041

0.036

0.037

0.023

0.046

2

0.004

0.027

0.041

0.034

0.035

0.019

0.046

3

0.003

0.022

0.040

0.033

0.034

0.015

0.045

4

0.003

0.021

0.041

0.033

0.034

0.017

0.045

5

0.003

0.020

0.040

0.032

0.032

0.021

0.046

6

0.005

0.020

0.040

0.033

0.036

0.031

0.045

7

0.010

0.022

0.040

0.033

0.042

0.042

0.044

8

0.027

0.029

0.040

0.035

0.044

0.041

0.041

9

0.048

0.037

0.041

0.038

0.037

0.034

0.036

10

0.048

0.043

0.042

0.042

0.032

0.029

0.030

11

0.046

0.042

0.042

0.044

0.033

0.027

0.024

12

0.055

0.039

0.041

0.045

0.033

0.025

0.016

13

0.063

0.040

0.041

0.046

0.032

0.021

0.012

14

0.059

0.042

0.041

0.047

0.033

0.021

0.011

15

0.062

0.045

0.041

0.047

0.035

0.021

0.011

16

0.068

0.048

0.042

0.048

0.037

0.026

0.012

17

0.091

0.051

0.042

0.049

0.044

0.031

0.019

18

0.139

0.052

0.043

0.049

0.053

0.044

0.038

19

0.129

0.056

0.044

0.048

0.058

0.084

0.048

20

0.072

0.061

0.044

0.048

0.060

0.117

0.060

21

0.032

0.065

0.045

0.048

0.062

0.113

0.083

22

0.014

0.069

0.045

0.047

0.060

0.096

0.098

23

0.009

0.064

0.044

0.044

0.052

0.063

0.085

24

0.005

0.050

0.039

0.041

0.045

0.039

0.059

 

Table 10: Seasonal Multipliers

Month

Oven and Cooktop

Televisions

Set-Top Boxes

Computers and Monitors

Residual MELs and Lighting

Jan

1.094

1.032

1.02

0.98

1.19

Feb

1.065

0.991

0.84

0.87

1.11

Mar

1.074

0.986

0.92

0.89

1.02

Apr

0.889

0.990

0.98

1.11

0.93

May

0.891

0.971

0.91

1.14

0.84

Jun

0.935

0.971

0.94

0.99

0.80

Jul

0.993

1.002

1.05

1.05

0.82

Aug

0.920

1.013

1.06

1.01

0.88

Sep

0.923

1.008

1.06

0.96

0.98

Oct

0.920

1.008

1.14

0.97

1.07

Nov

1.128

1.020

1.03

0.99

1.16

Dec

1.168

1.008

1.05

1.04

1.20