SECTION 100.0 – SCOPE

            

(a)  Buildings Covered.

The provisions of Part 6 apply to all buildings:

1.   That are of Occupancy Group A, B, E, F, H, M, R, S, or U; and

2.   For which an application for a building permit or renewal of an existing permit is filed (or is required by law to be filed) on or after the effective date of the provisions, or which are constructed by a governmental agency; and

3.   That are:

A.   Unconditioned; or

B.   Indirectly or directly conditioned, by mechanical heating or mechanical cooling, or process spaces; or

C.   Low-rise residential buildings that are heated with a non-mechanical heating system.

EXCEPTION 1 to Section 100.0(a): Qualified historic buildings, as regulated by the California Historic Building Code (Title 24, Part 8). Lighting in qualified historic buildings shall comply with the applicable requirements in Section 140.6(a)3Q.

EXCEPTION 2 to Section 100.0(a): Building departments, at their discretion, may exempt temporary buildings, temporary outdoor lighting or temporary lighting in an unconditioned building, or structures erected in response to a natural disaster. Temporary buildings or structures shall be completely removed upon the expiration of the time limit stated in the permit.

(b) Parts of Buildings Regulated.

The provisions of Part 6 apply to the building envelope, space-conditioning systems, water-heating systems, pool and spas, solar ready buildings, indoor lighting systems of buildings, outdoor lighting systems, and signs located either indoors or outdoors, in buildings that are

1.   Covered by Section 100.0(a), and

2.   Set forth in TABLE 100.0-A.

(c)  Habitable Stories.

1.   All conditioned space in a story shall comply with Part 6 whether or not the story is a habitable space.

2.   All unconditioned space in a story shall comply with the lighting requirements of Part 6 whether or not the story is a habitable space.

(d) Outdoor Lighting and Indoor and Outdoor Signs.

The provisions of Part 6 apply to outdoor lighting systems and to signs located either indoors or outdoors as set forth in TABLE 100.0-A.

(e)  Sections Applicable to Particular Buildings.

TABLE 100.0-A and this subsection list the provisions of Part 6 that are applicable to different types of buildings covered by Section 100.0(a).

1.   All buildings. Sections 100.0 through 110.10 apply to all buildings.

EXCEPTION to Section 100.0(e)1: Spaces or requirements not 'listed in TABLE 100.0-A.

2.   Newly constructed buildings.

A.   All newly constructed buildings. Sections 110.0 through 110.10 apply to all newly constructed buildings within the scope of Section 100.0(a). 'In addition’, newly constructed buildings shall meet the requirements of Subsections B, C, D or E, as applicable.

B.   Nonresidential, high-rise residential, and hotel/motel buildings that are mechanically heated or mechanically cooled.

i.    Sections applicable . Sections 120.0 through 140.8 apply to newly constructed nonresidential buildings, high-rise residential buildings, and hotels/motels that are mechanically heated or mechanically cooled.

ii.    Compliance approaches. In order to comply with Part 6 newly constructed nonresidential buildings, high-rise residential buildings, and hotels/motels that are mechanically heated or mechanically cooled must meet the requirements of:

a.   Mandatory measures: The applicable provisions of Sections 120.0 through 130.5; and

b.   Either:

(i)   Performance approach: Section 140.1; or

(ii)   Prescriptive approach: Sections 140.2 through 140.8.

C.   Unconditioned nonresidential buildings and process space. Sections 110.10, 120.6, 130.0 through 130.5, 140.3(c), 140.6, 140.7, and 140.8 apply to all newly constructed unconditioned buildings and 140.3(c), 140.1, and 141.0 for process spaces within the scope of Section 100.0(a).

D.   Low-rise residential buildings.

i.    Sections applicable. Sections 150.0 through 150.1 apply to newly constructed low-rise residential buildings.

ii.    Compliance approaches.  In order to comply with Part 6 newly constructed low-rise residential buildings must meet the requirements of:

a.   Mandatory measures: The applicable provisions of Sections 110.0 through 110.10, and 150.0; and

b.   Either:

(i)   Performance approach: Section 150.1(a) and (b); or

(ii)   Prescriptive approach: Section 150.1(a) and (c)

EXCEPTION 1 to Section 100.0(e)2Diib: Seasonally occupied agricultural housing limited by state or federal agency contract to occupancy not more than 180 days in any calendar year.

EXCEPTION 2 to Section 100.0(e)2Diib: Low-rise residential buildings that are heated with a wood heater or another nonmechanical heating system and that use no energy obtained from depletable sources for lighting or water heating.

E.  Covered Processes.

i.    Sections applicable. Sections 110.2, 120.6 and 140.9 apply to covered processes.

ii.    Compliance approaches. In order to comply with Part 6 covered processes must meet the requirements of:

a.   The applicable mandatory measures in Section 120.6; and

b.   Either:

(i)   The Performance approach requirements of Section 140.1; or

(ii)   The Prescriptive approach requirements of Section 140.9.

Note: If covered processes do not have prescriptive requirements, then only the applicable mandatory measures in Section 120.6 must be met.

3.   New construction in existing buildings.

A.   Nonresidential, high-rise residential, and hotel/motel buildings. Section 141.0 applies to new construction in existing buildings that will be nonresidential, high-rise residential, and hotel/motel occupancies.

B.   Low-rise residential buildings. Section 150.2 applies to new construction in existing buildings that will be low-rise residential occupancies.

4.   Installation of insulation in existing buildings. Section 110.8(d) applies to buildings in which insulation is being installed in existing attics, or on existing water heaters, or existing space conditioning ducts.

5.   Outdoor Lighting. Sections 110.9, 130.0, 130.2, 130.4, 140.7, and 150.0 apply to newly constructed outdoor lighting systems, and Section 141.0 applies to outdoor lighting that is either added or altered.

6.   Signs. Sections 130.0, 130.3 and 140.8 apply to newly constructed signs located either indoors or outdoors and Section 141.0 applies to sign alterations located either indoors or outdoors.

(f)  Mixed Occupancy.

When a building is designed and constructed for more than one type of occupancy (residential and nonresidential), the space for each occupancy shall meet the provisions of Part 6 applicable to that occupancy.

EXCEPTION 1 to Section 100.0(f): If one occupancy constitutes at least 80 percent of the conditioned floor area of the building, the entire building envelope, HVAC, and water heating may be designed to comply with the provisions of Part 6 applicable to that occupancy, provided that the applicable lighting requirements in Sections 140.6 through 140.8 or 150.0(k) are met for each occupancy and space and mandatory measures in Sections 110.0 through 130.5, and 150.0 are met for each occupancy and space.

EXCEPTION 2 to Section 100.0(f): If one occupancy constitutes at least 90 percent of the combined conditioned plus unconditioned floor area of the building, the entire building indoor lighting may be designed to comply with only the lighting provisions of Part 6 applicable to that occupancy.

(g) Administrative Requirements.

Administrative requirements relating to permit requirements, enforcement by the Commission, locally adopted energy standards, interpretations, claims of exemption, approved calculation methods, rights of appeal, and certification and labeling requirements of fenestration products and roofing products are specified in California Code of Regulations, Title 24, Part 1, Sections 10-101 to 10-114.

(h) Certification Requirements for Manufactured Equipment, Products, and Devices.

Part 6 limits the installation of the following manufactured equipment, products, and devices to:

1.   For items 'listed’ below that are regulated by Title 20, limited to those that have been certified to the Energy Commission by their manufacturer, pursuant to the provisions of Title 20 California Code of Regulations, Section 1606, to meet or exceed minimum specifications or efficiencies adopted by the Commission; or

2.   For items 'listed below that are required to be certified to the Energy Commission and are not regulated by Title 20, limited to those certified by the manufacturer in a declaration, executed under penalty of perjury under the laws of the State of California, that all the information provided pursuant to the certification is true, complete, accurate and in compliance with all applicable provisions of Part 6; and if applicable that the equipment, product, or device was tested under the applicable test method specified in Part 6; or

3.   For items 'listed below that are required to be 'listed in directories or certified by someone other than the Energy Commission, limited to those that comply with the applicable provisions of Item 4, below.

A.   Central air-conditioning heat pumps and other central air conditioners (Sections 110.1 and  110.2).

B.   Combination equipment: space heating and cooling, or space heating and water heating (Section 110.2(a)3).

C.   Fenestration products (Section 110.6).

D.   Fluorescent lamp ballasts (Section 110.1).

E.   Gas space heaters (Sections 110.1 and 110.2).

F.   Insulating materials and roofing products (Section 110.8).

G.   Lighting control devices and lighting control systems (Section 110.9).

H.   Oil-fired storage water heaters (Section 110.3).

I.    Other heating and cooling equipment (Sections 110.1 and 110.2).

J.   Plumbing fittings (Section 110.1).

K.   Pool heaters (Section 110.4).

L.   Refrigerators, refrigerator-freezers, and freezers (Section 110.1).

M.  Room air conditioners (Section 110.1).

N.   Slab floor perimeter insulation (Section 150.0 (l)).

O.   Water heaters (Section 110.3).

P.   Track lighting integral current limiter (Section 110.9).

Q.   High efficacy LED light sources (Section 110.9).

R.   Ballasts for residential recessed luminaires (Section 110.9).

4.   The certification status of any such manufactured device shall be confirmed only by reference to:

A.   A directory published or approved by the Commission; or  

B.   A copy of the application for certification from the manufacturer and the letter of acceptance from the Commission staff; or

C.   Written confirmation from the publisher of a Commission-approved directory that a device has been certified; or

D.   A Commission-approved label on the device.

5.   Part 6 does not require a builder, designer, owner, operator, or enforcing agency to test any certified device to determine its compliance with minimum specifications or efficiencies adopted by the Commission.

TABLE 100.0-A  APPLICATION OF STANDARDS

Occupancies

Application

Mandatory

Prescriptive

Performance

Additions/Alterations

General Provisions

100.0, 100.1, 100.2, 110.0, 110.10

Nonresidential, High-Rise Residential, And Hotels/Motels

General

140.0

140.2

140.1

141.0

Envelope (conditioned)

110.6, 110.7, 110.8, 120.7

140.3

Envelope (unconditioned process spaces)

N.A.

140.3(c)

HVAC (conditioned)

110.2, 110.5, 120.0-120.5, 120.8

140.4

Water Heating

110.3, 120.3, 120.8

140.5

Indoor Lighting (conditioned, process spaces)

110.9, 120.8, 130.0, 130.1, 130.4

140.3(c), 140.6

Indoor Lighting (unconditioned and parking garages)

110.9, 120.8, 130.0, 130.1, 130.4

140.3(c),140.6

N.A.

Outdoor Lighting

 

110.9, 130.0, 130.2, 130.4

140.7

Building Electrical Power

130.5

N.A.

Pool and Spa Systems

110.4, 150.0(p)

N. A.

N. A.

Solar Ready Buildings

110.10

N.A.

N.A.

Covered Processes1

Envelope, Ventilation, Process Loads

 

110.2, 120.6, 120.8

 

140.9

140.1

120.6, 140.9

Signs

Indoor and Outdoor

130.0, 130.3

140.8

N.A.

141.0

Low-Rise Residential

General

150.0

150.1(a, c)

150.1(a, b)

150.2

Envelope (conditioned)

110.6, 110.7, 110.8, 150.0(a-e, g, l)

HVAC (conditioned)

110.2, 110.5, 150.0(h, i, m, o)

Water Heating

110.3, 150.0(j, n)

Indoor Lighting (conditioned, unconditioned and parking garages)

110.9, 130.0, 150.0(k)

Outdoor Lighting

110.9, 130.0, 150.0(k)

Pool and Spa Systems

110.4, 150.0(p)

N. A.

N.A.

N.A.

Solar Ready Buildings

110.10

N. A.

N.A.

N.A.

1 Nonresidential, high-rise and hotel/motel buildings that contain covered processes may conform to the applicable requirements of both occupancy types 'listed in this table.